Toshiba Strata DK 280 Installation Manual page 369

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Speed Dial Memory.
The three-minute
setting is
recommended
if station
users frequently
store
memos with Speed Dial numbers using the MODE
button below the Liquid Crystal Display (LCD).
q
Built-in Auto Attendant
Camp-on
Busy/Ring
No
Answer
Routing,
LED 18 is designed
for Auto
Attendant
configurations
that
have
primary
announcement
devices, but no secondary
ones-
tells the system
where to route Auto Attendant
calls that ring and are not answered
or have been
camped-on
for a designated
time (see Program
26). The calls can be sent back to the primary
announcement
device or to the station or stations
assigned
to the CO lines' normal ringing pattern
(see Programs 81, 84, and 87).
q
Built-in Auto Attendant
Disconnect
Time, LEDs
16 and 17-If
LED 18 is assigned
for normal
ringing,
set LEDs 16 and 17 to tell the system
when to disconnect
Built-in Auto Attendant
calls
that have not been answered
by the alternative
stations.
This feature
assures that the loop start
CO line that the call was made on will be free for
other calls if the caller hangs up before answered.
The initialized
disconnect
setting is 40 seconds.
The other
timing
options
available
are 150
seconds and 350 seconds.
Set LEDs 16 and 17
for the desired time as follows:
+
40 seconds: LED 16 = Off. LED 17 = Off.
+
120 seconds: LED 16 = Off. LED 17 = On.
+
240 seconds: LED 16 = On. LED 17 = Off.
W Built-in
Auto Attendant
MOH/RBT
for Transfer,
LED 15-Callers
can hear ring back tone (RBT) or
Music-on-hold
(MOH) after being transferred
from
the Built-in Auto Attendant
to a station, depending
on the selection made with LED 15.
H
RS-232
Voice
Mail Signaling
Method
(LED
14)-The
DK280
provides
two types of RS-232
signaling:
Bellcore
Standard
type (TR-TSY-
000283, TR-NWT-000283)
or Toshiba Proprietary.
Refer
to
the
VM
machine
installation
documentation
and contact the Toshiba and/or VM
machine
manufacturer
for VM machine
SMDI
configuration.
Notes:
1.
Toshiba
VP products
require
Release
7
software
or above for
Toshiba
proprietary
integration.
2.
Toshiba
VP products
require
the "SW-
X0042 feature package
(C. 0. Centrex) for
SMDI, but not for Toshiba Proprietary
RS-
232 Interface.
3.
Toshiba Stratagy products
support
SMDI
only in the standard
configuration,
not
Toshiba proprietary
RS-232 interface.
q
SMDI Station
Number
Digit Length
(LED 13-
lo)--This
refers to the station digit length that the
SMDI voice mail system
design
requires.
This
parameter
is set for the Voice Mail system digit
length; not the DK280 station digit length.
If the
voice
mail system
SMDI
is designed
per the
Bellcore Standard TR-TSY-000283,
1985 version,
set this parameter
to seven-digits
(LEDs 10, 11,
and 12 "On" which is equal to Hex 7). Current VP
and Stratagy
voice
mail SMDI
systems
are
designed for this seven-digit operation.
If the voice
mail system
SMDI is designed
per the Bellcore
Standard TR-NWT-000283,
1991 version, set this
parameter
between
l-10 dig+
with LEDs 10, 11,
12, and 13. (See Program
10-3 record sheet for
LED-HEX
values.)
Digit length
setting
is not
necessary with Toshiba Proprietary Interface (LED
lo-13 OFF).
n
(LED 08)-This
option
determines
if Caller ID
(CLID)
and/or
Automatic
Number
Identification
(ANI) telephone
numbers
will be sent out the
system
SMDI
port
(SMDI
only
not Toshiba
proprietary):
+
Turn
LED 08, 10, 11, 12, and 13 "ON" if
received Caller ID and/or ANI numbers should
be sent out the system SMDI port.
,
+
Turn
LED 08 "OFF"
if received
Caller
ID
and/or ANI numbers
should not be sent out
the system SMDI port.
+
The system will initialize with LED 08 "OFF" -
no CLID or ANI information
will be sent out the
SMDI port.
n
SMDI Bellcore
Standard
Version
(LED 09)-
Bellcore
released
two versions
of the SMDI
specification.
Contact
your voice mail machine
vendor to determine
which specification
to enable
with this program - TR-TSY-000283,
Issue 1, July
1985 version,
or the TR-NWT-000283,
Issue 2,
May 1991 version. Toshiba VP and Stratagy SMDI
products currently use the 1985 version. In either
case, the VM station digit length must be set with
LED lo-13
as shown above.
Also note that the
1985 and 1991 version Bellcore specifications
use
different space/character
parameters
for some call
types which means the DK280 will not operate
January
1996
9-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents