Music-On-Hold (Moh)/Background Music (Bgm) Options - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Note:
MOH
Installation
The -24V (Pin 25) and DG (Pin 50) ground
terminals are available
on the RSTU, RDSU,
or PSTU only, not on the PEW.
Install
the
MOH
option
in accordance
with the
.
following steps: (Refer to Figure 6-2.)
1.
8.
To test the operation
of the DPFT, turn the system
power switch OFF, and verify that CO dial tone is
available at each standard
telephone
connected
to
the DPFT. Also, call back to each telephone
using
an outside line.
Connect
the external
music source to the RCTU
RCA Jack.
2.
6.2
Music-on-Hold
(MOH)/
Background
Music (BGM)
Options
Rotate the RCTU volume control (VRl) to adjust
MOH
volume:
clockwise
increases
volume;
counterclockwise
decreases
volume.
Listen to the
CO line on-hold when setting MOH to the proper
volume.
3.
Strata DK280 systems provide an MOH option for CO,
E&M tie and DID lines and telephones
connected
to
the system.
A variety
of BGM options
are also
provided. (Refer to Figure 6-2.)
If MOH relay control is required,
access Program
77-i.
Set
LED
05 to ON to configure
the
MOH/Night
Transfer
Control
relay for the MOH
function. This feature requires the installation
of a
PIOU, PIOUS, or PEPU PCB.
4.
6.2.1 MOH Option
The RCTU supports
an external,
customer-provided
music source-such
as a tuner, compact
disc player,
or tape player-for
MOH. The PIOU,
PIOUS,
and
PEPU each
has a relay contact
on it that can be
configured
to automatically
turn the source on when a
CO line or station is placed on hold. MOH source and
MOH relay contact specifications
are as follows:
If using the MOH control feature
with a PIOU or
PEPU, set PIOU or PEPU jumper plug Pll to the
MAKE or BREAK position as required:
1
MAKE
(M)-Shorts
the
normally
open
contacts
(pins
9 and
34) when
MOH
is
activated.
n
BREAK
(B)-Opens
the normally
closed
contacts
(pins
9 and
34) when
MOH
is
activated.
n
BGM or MOH Source Specifications
+
Input Impedance:
600 ohms or 8 ohms
4
Input Voltage (recommended
levels)
l
Minimum: 0.14 VRMS (-15 dBm)
l
Maximum:
0.77 VRMS (0 dBm)
n
Relay Contact Specifications
+
Voltage: 24VDC maximum
+
Current: 1 ampere maximum
If using the MOH Control feature
with a PIOUS,
solder PIOUS jumper W2 to the MAKE or BRtAK
position as required:
1
MAKE
(M)-Shorts
the
normally
open
contacts (NHT and NHR) when any CO line is
in the hold condition.
n
BREAK
(B)-Opens
the normally
closed
contacts (NHT and NHR) when any CO line is
in the hold condition.
IMPORTANT
!
5.
In accordance
with U.S. Copyright
Law, a
license may be required
from the American
Society
of
Composers,
Authors,
and
Publishers
(ASCAP),
or
other
similar
organization,
if
copyrighted
music
is
transmitted
through the Music-on-Hold
feature
of this telecommunications
system.
Toshiba
America
lnforma tion Systems,
Inc., hereby
disclaims any liability arising out of the failure
to obtain such a license.
MOH (CO line or intercom
hold) is applied
from
the RCTU through the KSU cabinet's backplane to
DID lines, tie lines, CO lines, electronic,
digital,
and standard telephones
on hold.
6.
MOH
is also
applied
through
the
RCTU
Page/BGM
control
to
provide
BGM
to
electronic/digital
telephone
speakers
and external
page. (Refer to Subsection
6.2.2.)
- or -
.
January
1996
6-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents