ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
Network Login Commands
10 Gigabit Ethernet ports such as those on the 10G4X I/O module and the uplink ports on the
Summit X450 family of switches do not support netlogin MAC-based VLANs.
If you attempt to configure netlogin MAC-based VLANs on 10 Gigabit Ethernet ports, the switch
displays an error message similar to the following:
ERROR: The following ports do not support the MAC-Based VLAN mode; 1, 2, 10
You can have a maximum of 1,024 MAC addresses per I/O module or per Summit X450 family
switch.
Displaying FDB Information. To view netlogin-related FDB entries, use the following command:
show fdb netlogin [all | mac-based-vlans]
The following is sample output from the
Mac
------------------------------------------------------------------------
00:04:96:10:51:80
00:04:96:10:51:81
00:04:96:10:51:91
00:04:96:10:51:11
00:04:96:10:51:31
Flags : d - Dynamic, s - Static, p - Permanent, n - NetLogin, m - MAC, i - IP,
x - IPX, l - lockdown MAC, M - Mirror, B - Egress Blackhole,
b - Ingress Blackhole, v - NetLogin MAC-Based VLAN.
The flags associated with netlogin include:
—Indicates the FDB entry was added because the port is part of a MAC-Based virtual port/VLAN
v
combination.
—Indicates the FDB entry was added by network login.
n
Displaying Port and VLAN Information. To view information about the VLANs that are temporarily added
in MAC-based mode for netlogin, use the following command
show ports <port_list> information detail
The following is sample output from this command:
Port:
1
Virtual-router: VR-Default
Type:
Random Early drop:
Admin state:
Link State:
Link Counter: Up
VLAN cfg:
Name: Default, Internal Tag = 1(MAC-Based), MAC-limit = No-limit
...<truncated output>
Egress 802.1p Replacement:
NetLogin:
NetLogin authentication mode:
NetLogin port mode:
Smart redundancy:
1066
show fdb mac-based-vlans
Vlan
Age
VLONE(0021)
0086
VLTWO(0051)
0100
VLTWO(0051)
0100
VLTWO(0051)
0100
VLTEN(0051)
0100
UTP
Disabled
Enabled with
auto-speed sensing
Active, 100Mbps, full-duplex
1 time(s)
Disabled
Enabled
Mac based
MAC based VLANs
Enabled
command:
Use
Flags
Port List
0000
n m
v 1:11
0000
n m
v 1:11
0000
n m
v 1:11
0000
n m
8:1
0000
d m
8:10
auto-duplex
ExtremeWare XOS 11.5 Command Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.5

Table of Contents