CAUTION:
Before router installation begins, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with
an incorrectly attached lug can damage the router.
Connect the grounding cable to a proper earth ground.
1.
Verify that a licensed electrician has attached the cable lug provided with the router
2.
to the grounding cable.
Make sure that grounding surfaces are clean and brought to a bright finish before
3.
grounding connections are made.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
4.
the strap to one of the ESD points on the chassis. For more information about ESD,
see
"Preventing Electrostatic Discharge Damage to a T320 Router" on page
Place the grounding cable lug over the grounding points.The left pair is sized for M6
5.
bolts, and the right pair is sized for UNC 1/4-20 bolts.
Secure the grounding cable lug to the grounding points, first with the washers, then
6.
with the screws.
Verify that the grounding cabling is correct, that the grounding cable does not touch
7.
or block access to router components, and that it does not drape where people could
trip on it.
Tools and Parts Required to Ground the T320 Router on page 151
T320 Chassis Description on page 13
Preventing Electrostatic Discharge Damage to a T320 Router on page 330