SVS Operation

6.2 SVS Operation
The SVS detects if the AV
configured to provide a POR or set a flag, when a low-voltage condition occurs.
The SVS is disabled after a brownout reset to conserve current consumption.
6.2.1

Configuring the SVS

The VLDx bits are used to enable/disable the SVS and select one of 14
threshold levels (V
VLDx = 0 and on when VLDx > 0. The SVSON bit does not turn on the SVS.
Instead, it reflects the on/off state of the SVS and can be used to determine
when the SVS is on.
When VLDx = 1111, the external SVSIN channel is selected. The voltage on
SVSIN is compared to an internal level of approximately 1.2 V.
6.2.2

SVS Comparator Operation

A low-voltage condition exists when AV
or when the external voltage drops below its 1.2-V threshold. Any low-voltage
condition sets the SVSFG bit.
The PORON bit enables or disables the device-reset function of the SVS. If
PORON = 1, a POR is generated when SVSFG is set. If PORON = 0, a
low-voltage condition sets SVSFG, but does not generate a POR.
The SVSFG bit is latched. This allows user software to determine if a
low-voltage condition occurred previously. The SVSFG bit must be reset by
user software. If the low-voltage condition is still present when SVSFG is reset,
it will be immediately set again by the SVS.
6-4
Supply Voltage Supervisor
voltage drops below a selectable level. It can be
CC
) for comparison with AV
(SVS_IT−)
drops below the selected threshold
CC
The SVS is off when
CC.