Continuous Mode
In continuous mode the timer repeatedly counts up to TBR
from zero as shown in Figure 12−4. The compare latch TBCL0 works the same
way as the other capture/compare registers.
Figure 12−4. Continuous Mode
TBR (max)
0h
The TBIFG interrupt flag is set when the timer counts from TBR
Figure 12−5 shows the flag set cycle.
Figure 12−5. Continuous Mode Flag Setting
Timer Clock
Timer
Set TBIFG
TBR (max) −1 TBR (max)
0h
Timer_B Operation
(max)
1h
TBR (max) −1
TBR (max)
Timer_B
and restarts
to zero.
(max)
0h
12-7