01/FORK, TRIPLE CLAMP
changing the lower DU bush
5.13
–
Measure the run-out of the inner tube.
Run-out of inner tube
»
If the measured value is greater than the specified value:
–
Change the inner tube.
200631-10
–
Check the outer tube for damage.
»
If there is damage:
–
Change the outer tube.
200632-10
–
Check the surface of the upper DU bush.
»
If the bronze-colored layer
–
Change the outer tube.
–
Check the surface of the lower DU bush.
»
If the bronze-colored layer under the sliding layer is visible:
–
Change the lower DU bush. (
200665-10
–
Check the spring length.
Guideline
Spring length with preload spacer(s)
»
If the measured value is greater than the specified value:
–
Reduce the thickness of the preload spacer.
»
If the measured value is less than the specified value:
–
Increase the thickness of the preload spacer.
200666-10
–
Disassemble the outer tubes. (
–
Heat the outer tube in the area of the lower DU bush.
Guideline
50 °C (122 °F)
–
Remove DU bush
–
Press the new DU bush all the way in.
–
Assemble the outer tubes. (
200664-10
≤ 0.20 mm (≤ 0.0079 in)
under the sliding layer
p. 26)
405 mm (15.94 in)
p. 24)
.
p. 27)