ENGINE CONTROL TROUBLE CODE
Secondary air valve - the control wire has a short circuit to sensor ground
Condition
The ignition is off.
The EFI control unit is disconnected. (
The break out box is connected to the wiring harness.
The exhaust air injection valve is disconnected. (
Secondary air valve - check the control wire for a short circuit to sensor ground.
Measure the resistance between the specified points.
Break out box CO pin 13 – Break Out Box AO pin 7
Resistance
»
If the specifications have not been met:
Check the cable from EFI control unit connector CO (
sensor ground.
»
If the specifications have been met:
Contact customer service.
p. 227)
p. 190)
600850-12
600850-11
∞ Ω
p. 397) pin 13 to connector CK (
p. 396) pin 2 for a short circuit to