B.7 H Parameters: Multi-Function Terminals
B.7 H Parameters: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
u

H1: Multi-Function Digital Inputs

No.
(Addr.
Name
Hex)
Multi-Function Digital
H1-01
Input Terminal S1
(0438)
Function Selection
Multi-Function Digital
H1-02
Input Terminal S2
(0439)
Function Selection
Multi-Function Digital
H1-03
Input Terminal S3
(0400)
Function Selection
Multi-Function Digital
H1-04
Input Terminal S4
(0401)
Function Selection
Multi-Function Digital
H1-05
Input Terminal S5
(0402)
Function Selection
Multi-Function Digital
H1-06
Input Terminal S6
(0403)
Function Selection
Multi-Function Digital
H1-07
Input Terminal S7
(0404)
Function Selection
Multi-Function Digital
H1-08
Input Terminal S8
(0405)
Function Selection
<1> Value in parenthesis is the default setting when a 3-Wire initialization is performed (A1-03 = 3330).
H1-oo Setting
Function
0
3-Wire sequence
LOCAL/REMOTE
1
selection
External reference 1/2
2
selection
Multi-Step Speed
3
Reference 1
Multi-Step Speed
4
Reference 2
Multi-Step Speed
5
Reference 3
6
Jog reference selection Jog Freq Ref
288
LCD Display
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S1 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S2 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S3 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S4 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S5 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S6 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S7 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S8 Func Sel
Note:
H1 Multi-Function Digital Input Selections
LCD Display
Closed: Reverse rotation (only if the drive is set up for 3-Wire sequence)
3-Wire Control
Terminals S1 and S2 are automatically set up for the Run command and
Stop command.
Open: REMOTE (parameter settings determine the source of the frequency
Reference 1 or 2 (b1-01, b1-02 or b1-15, b1-16)
Local/Remote Sel
Closed: LOCAL, Frequency reference and Run command are input from
the digital operator.
Open: Run command and frequency reference source 1 (determined by
b1-01 and b1-02)
Ext Ref Sel
Closed: Run command and frequency reference source 2 (determined by
b1-15 and b1-16)
When input terminals are set to Multi-Step Speed References 1 through 3,
Multi-Step Ref 1
switching combinations of those terminals will create a multi-step speed
sequence using the frequency references set in d1-01 through d1-08.
When input terminals are set to Multi-Step Speed References 1 through 3,
Multi-Step Ref 2
switching combinations of those terminals will create a multi-step speed
sequence using the frequency references set in d1-01 through d1-08.
When input terminals are set to Multi-Step Speed References 1 through 3,
Multi-Step Ref 3
switching combinations of those terminals will create a multi-step speed
sequence using the frequency references set in d1-01 through d1-08.
Closed: Jog frequency reference (d1-17) selected. Jog has priority over all
other reference sources.
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Description
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
288
to
291
for descriptions of setting values.
Set unused terminals to F.
Description
Values
Page
Default: 40 (F)
<1>
152
Min.: 1
Max.: 9F
Default: 41 (F)
<1>
152
Min.: 1
Max.: 9F
Default: 24
Min.: 0
152
Max.: 9F
Default: 14
Min.: 0
152
Max.: 9F
<1>
Default: 3 (0)
152
Min.: 0
Max.: 9F
<1>
Default: 4 (3)
152
Min.: 0
Max.: 9F
<1>
Default: 6 (4)
152
Min.: 0
Max.: 9F
Default: 8
Min.: 0
152
Max.: 9F