Configuring Global Settings For Cfm - Edge-Core ECS4810-12M Layer 2 Management Manual

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

| Basic Administration Protocols
C
15
HAPTER
Connectivity Fault Management
C
G
ONFIGURING
LOBAL
S
CFM
ETTINGS FOR
Configure the local maintenance end points (MEPs) which will serve as
3.
the domain service access points for the specified maintenance
association using the MEP List (see
Associations").
Enter a static list of MEPs assigned to other devices within the same
4.
maintenance association using the Remote MEP List (see
Remote Maintenance End
verify the functionality of these remote end points by cross-checking
the static list configured on this device against information learned
through continuity check messages.
Enable CFM globally on the switch using the Configure Global screen
5.
(see
"Configuring Global Settings for
Enable CFM on the local MEPs using the Configure Interface screen (see
6.
"Configuring Interfaces for
Enable continuity check and cross-check operations, and configure AIS
7.
parameters using the Configure MA – Configure Details screen (see
"Configuring CFM Maintenance
Other configuration changes may be required for your particular
environment, such as adjusting the interval at which continuity check
messages are sent (see
setting the start-up delay for the cross-check operation (see
Global Settings for
CFM"). You can also enable SNMP traps for events
discovered by continuity check messages or cross-check messages (see
"Configuring Global Settings for
Use the Administration > CFM (Configure Global) page to configure global
settings for CFM, such as enabling the CFM process on the switch, setting
the start-up delay for cross-check operations, configuring parameters for
the link trace cache, and enabling traps for events discovered by continuity
check messages or cross-check messages.
CLI R
EFERENCES
"CFM Commands" on page 1093
P
ARAMETERS
These parameters are displayed:
Global Configuration
CFM Status – Enables CFM processing globally on the switch.
(Default: Enabled)
To avoid generating an excessive number of traps, the complete CFM
maintenance structure and process parameters should be configured
prior to enabling CFM processing globally on the switch. Specifically, the
maintenance domains, maintenance associations, and maintenance
end-points (MEPs) should be configured on each participating bridge
using the Configure MD page (see
– 452 –
"Configuring CFM Maintenance
Points"). This allows CFM to automatically
CFM").
CFM").
Associations").
"Configuring CFM Maintenance
CFM").
"Configuring CFM Maintenance
"Configuring
Associations"), or
"Configuring