E
XAMPLE
Console(config-erps)#enable
Console(config-erps)#
R
ELATED
erps (920)
This command sets the guard timer to prevent ring nodes from receiving

guard-timer

outdated R-APS messages. Use the no form to restore the default setting.
S
YNTAX
guard-timer milliseconds
D
EFAULT
500 milliseconds
C
OMMAND
ERPS Configuration
C
OMMAND
The guard timer duration should be greater than the maximum expected
forwarding delay for an R-APS message to pass around the ring. A side-
effect of the guard timer is that during its duration, a node will be unaware
of new or existing ring requests transmitted from other nodes.
E
XAMPLE
Console(config-erps)#guard-timer 300
Console(config-erps)#
This command sets the timer to filter out intermittent link faults. Use the

holdoff-timer

no form to restore the default setting.
S
YNTAX
holdoff-timer milliseconds
C
OMMANDS
milliseconds - The guard timer is used to prevent ring nodes from
receiving outdated R-APS messages. During the duration of the
guard timer, all received R-APS messages are ignored by the ring
protection control process, giving time for old messages still
circulating on the ring to expire. (Range: 10-2000 milliseconds, in
steps of 10 milliseconds)
S
ETTING
M
ODE
U
SAGE
milliseconds - The hold-off timer is used to filter out intermittent
link faults. Faults will only be reported to the ring protection
mechanism if this timer expires. (Range: 0-10000 milliseconds, in
steps of 100 milliseconds)