6 Service Tasks

6.1  Inspecting the General Condition
❒ Check all safety-related components for corrosion, repair if required and reapply corro-
sion protection.
❒ Check weld seams.
❒ Check tightness of screw connections; replace thread-locking compound if required; ob-
serve any defined torque specifications; replace defective screws (e. g. in case of corro-
sion).
❒ Check cables for ruptures, signs of wear and proper attachment; replace defective com-
ponents.
❒ Check cable connections and plug connections.
6.2  Fuse Replacement
The 100 A fuse is located in a fuse housing on the side of the drive unit sustainer next to the
charging receptacle.
Preparation:
❒ Turn the control unit off.
Steps:
1. Open the hinged cover of the fuse housing.
2. Pull out the fuse and replace if required.
Properly reassemble all components upon completion of the work.
1
figure 8
fuse housing with inserted fuse
1 Fuse housing with open cover
2 Fuse