CAUTION
Risk of injury due to uncontrolled movements. The fuse must always be removed for any mainte-
nance work where the battery cover is open.
CAUTION
Risk of injury during tasks that involve lifting. The weight of a battery is approximately 40 kg. When
removing or installing the batteries, use hoisting devices of sufficient capacity or complete these tasks
with the support of a helper.
NOTICE
Risk of damage due to improper preparation of maintenance tasks.
• If the driving function is not required, turn off the control unit or jack up the drive wheels in order to
prevent uncontrolled operation through accidental joystick activation.
• Water must not come into direct contact with the electronics or battery during maintenance tasks.
• When attaching plug connections on the controller, ensure the contacts are assigned correctly.
NOTICE
Risk of battery damage due to falling. Hoisting devices used for transportation must have a sufficient
capacity. Secure the batteries against falling.
NOTICE
Risk of battery damage.
• Always remove the main fuse before doing any work on the batteries. In order to prevent short cir-
cuits, always use insulated tools.
• Prevent deep discharge of the batteries in order to avoid loss of functionality and permanent battery
damage.
• Ensure correct polarity is used when connecting the batteries. The black cable must be connected
to the negative pole and the red cable to the positive pole.
NOTICE
Risk of damage to the battery charger. Prevent overheating of the charger during the charging proc-
ess. Ensure that the cooling ribs on the back of the device are not covered.
INfORMATION
For the purpose of shipping or when the C2000 power wheelchair is not being used for an extended
period of time, remove the fuse
from the battery case in order to prevent deep discharge of the batteries due to standby current.
INfORMATION
The power wheelchair has been tested according to EMC regulations. The following particularities
must be observed when using the wheelchair:
• The driving characteristics of the power wheelchair can be affected by electromagnetic fields (mo-
bile phones or other radiating devices). Therefore all mobile devices must be turned off when driving.
• The power wheelchair can generate electromagnetic fields that can cause interference with other
devices. Therefore, turn off the control unit whenever you do not need it.