Ac Input Wire; Ac Wire Input Connection For 6000 W; Table 2.2 Ac Wire Specification For 6000 Watt Units; Table 2.3 Ac Wire Specification For 12000 Watt Units - Xantrex XDC 10-600 Operating Manual

6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-600:
Table of Contents

Advertisement

AC Input Wire The manufacturer recommends the AC input wire specified in Table 2.2 and
Table 2.3. This must be permanently connected to an approved AC distribution box
with suitably rated over-current protection. If you require a special cord, contact the
manufacturer.

Table 2.2 AC Wire Specification for 6000 Watt units

AC Input Voltage Range
190–242Vac, 47–63Hz,
3-phase, 4 wire (standard)
342–500Vac, 47–63Hz,
3-phase, 4 wire (HV-Input)

Table 2.3 AC Wire Specification for 12000 Watt units

AC Input Voltage Range
190–242Vac, 47–63Hz,
3-phase, 4 wire (standard)
342–500Vac, 47–63Hz,
3-phase, 4 wire (HV-Input)
AC Wire Input
See Figure 2.5, on page 42.
Connection
To connect the 6000 W AC input wires:
for 6000 W
1. Ensure that the AC input cord is de-energized, and that the power switch on the
front of the power supply is OFF.
2. Strip approximately 4 in. (10 cm) from the jacket of the AC wire. Strip 0.55 in.
(14 mm) at the end of each wire.
3. Undo the 2 screws for the AC wiring strain relief/cover on the rear panel.
Remove the cover.
4. Undo the strain relief screws. Insert the AC input cable through the strain relief
until the outer cable jacket is flush with the inside of the strain relief. Tighten the
strain relief cable clamp screws.
5. Insert the ground wire (green) 0.55 in. (14 mm) into the left-most terminal
location, and tighten securely. (The safety ground wire may alternatively be
connected to the chassis ground stud next to the terminal block, using a suitably
sized ring terminal).
Release 3.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Wire
4 x 10 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 300V, 0.800 in. maximum
cable diameter, rated for 25A.
4 x 14 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 600V, 0.800 in. maximum
cable diameter, rated for 13A.
Wire
4 x 6 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 300V, outside diameter
(OD) of cable is ≤ 1 in., rated for 50 A.
4 x 10 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 600V, outside diameter
(OD) of cable is ≤ 1 in., rated for 25 A.
Installation
AC Input Power
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents