Table B.3 Commands For Output Control - Xantrex XDC 10-600 Operating Manual

6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-600:
Table of Contents

Advertisement

Table B.3Commands for Output Control
SCPI Command
Function
Set (Immediate) Current
[[:]SOURce][<channel>]:CURRent[:LEVel][:IMMediate][:A
Setpoint
MPLitude] {<current>|MAXimum|MINimum}
Set Triggered Current
[[:]SOURce][<channel>]:CURRent[:LEVel]:TRIGgered[:AMP
Setpoint
Litude] {<current>|MAXimum|MINimum|DEFault}
Set (Immediate) Power
[[:]SOURce][<channel>]:POWer[:LEVel][:IMMediate][:AMP
Setpoint
Litude] {<power>|MAXimum|MINimum}
Set Triggered Power
[[:]SOURce][<channel>]:POWer[:LEVel]:TRIGgered[:AMPLi
Setpoint
tude] {<power>|MAXimum|MINimum|DEFault}
Set (Immediate)
[[:]SOURce][<channel>]:VOLTage[:LEVel][:IMMediate][:A
Voltage Setpoint
MPLitude] {<voltage>|MAXimum|MINimum}
Set Triggered Voltage
[[:]SOURce][<channel>]:VOLTage[:LEVel]:TRIGgered[:AMP
Setpoint
Litude] {<voltage>|MAXimum|MINimum|DEFault}
Set Voltage Slew Rate
[[:]SOURce][<channel>]:VOLTage:SLEW:STEP{<slewrate-vo
Voltage
ltage>|MAXimum|MINimum|DEFault}
Set Voltage Slew Rate
[[:]SOURce][<channel>]:VOLTage:SLEW:INTerval{<slewrat
Interval
e-interval>|MAXimum|MINimum|DEFault}
Set Over Current
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER][:LEV
Protection Level
el] {<current>|MAXimum|MINimum}
Set Over Current
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]:STAT
Protection
e <on-off-state>
Shutdown State
Query Over Current
[[:]SOURce][<channel>]:CURRent:PROTection[:OVER]:TRIP
Protection Tripped
ped?
Set Under Current
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer[:LEVe
Protection Level
l] {<current>|MAXimum|MINimum}
Set Under Current
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:STATe
Protection
<on-off-state>
Shutdown State
Query Under Current
[[:]SOURce][<channel>]:CURRent:PROTection:UNDer:TRIPp
Protection Tripped
ed?
Set Over Power
[SOURce][<channel>]:POWer:PROTection[:OVER][:LEVel]
Protection Level
{<power>|MAXimum|MINimum}
Set Over Power
[SOURce][<channel>]:POWer:PROTection[:OVER]:STATe
Protection
<on-off-state>
Shutdown State
Query Over Power
[[:]SOURce][<channel>]:POWer:PROTection[:OVER]:TRIPpe
Protection Tripped
d?
Set Under Power
[[:]SOURce][<channel>]:POWer:PROTection:UNDer[:LEVel]
Protection Level
{<power>|MAXimum|MINimum}
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Query
Change current setpoint
Yes
Change triggered current setpoint
Yes
Change power setpoint
Yes
Change triggered power setpoint
Yes
Change voltage setpoint
Yes
Change triggered votlage setpoint
Yes
Sets the voltage slew rate voltage change
Yes
for the programmed time interval
Sets the voltage slew rate time interval for
Yes
the programmed voltage change
Set the over current protection level
Yes
Select over current protection to
Yes
shutdown(ON) or set alarm (OFF)
Query if over current protection mechanism
N/A
has tripped
Set under current protection level
Yes
Select under current protection to shutdown
Yes
(ON) or set alarm (OFF)
Query if under current protection
N/A
mechanism has tripped
Set the over power protection level
Yes
Select over power protection to shutdown
Yes
(ON) or set alarm (OFF)
Query if over power protection mechanism
N/A
has tripped
Set under power protection level
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents