Xantrex XDC Series Operating Manual

Xantrex XDC Series Operating Manual

6000 watt slave power supply

Advertisement

Quick Links

TM-XDSL-01XN.book Page i Tuesday, November 5, 2002 3:22 PM
XDC 6000 Watt Series
Slave Power Supply
XDC 10-600SL
XDC 20-300SL
XDC 30-200SL
XDC 40-150SL
XDC 60-100SL
XDC 80-75SL
XDC 100-60SL
XDC 150-40SL
XDC 300-20SL
XDC 600-10SL
Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for Xantrex XDC Series

  • Page 1 TM-XDSL-01XN.book Page i Tuesday, November 5, 2002 3:22 PM XDC 10-600SL XDC 20-300SL XDC 30-200SL XDC 40-150SL XDC 60-100SL XDC 80-75SL XDC 100-60SL XDC 150-40SL XDC 300-20SL XDC 600-10SL Operating Manual XDC 6000 Watt Series Slave Power Supply...
  • Page 2 TM-XDSL-01XN.book Page ii Tuesday, November 5, 2002 3:22 PM...
  • Page 3 TM-XDSL-01XN.book Page i Tuesday, November 5, 2002 3:22 PM Operating Manual for XDC 6000 Watt Series Slave Power Supply...
  • Page 4 What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge, provided that you notify Xantrex of the product defect within the Warranty Period, and provided that Xantrex through inspection establishes the existence of such a defect and that it is covered by this Limited Warranty.
  • Page 5 Xantrex or its authorized service centers (hereafter “ASCs”);...
  • Page 6 APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY. IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, COSTS OR EXPENSES...
  • Page 7 Specifically, please note that this power supply is not intended for use in connection on Use with life support systems and Xantrex makes no warranty or representation in connection with any use of the product for such purposes. Xantrex Technology, Inc.
  • Page 8 DC voltage of the battery, will provide adequate reverse polarity current protection. Where several power supplies are in parallel, it is best to fuse each one, rather than one large fuse for all. Operating Manual for XDC Series Slave Power Supply...
  • Page 9 TM-XDSL-01XN.book Page vii Tuesday, November 5, 2002 3:22 PM Approvals CE Mark CE-marked units meet the following standards: • IEC 1010-1-92 including Amendments 1 and 2: • Overvoltage Category II • Permanently Connected Equipment • Pollution Degree 2 • EN50081-2-1996 Electromagnetic Generic Emission - Industrial Equivalent •...
  • Page 10 TM-XDSL-01XN.book Page viii Tuesday, November 5, 2002 3:22 PM Operating Manual for XDC Series Slave Power Supply viii...
  • Page 11: About This Manual

    This manual is intended to be used in conjunction with the full digital front panel XDC Series Operating manual. If you do not plan to use this power supply in a system with a full digital front panel XDC Series power supply, please contact the manufacturer for additional application data.
  • Page 12 TM-XDSL-01XN.book Page x Tuesday, November 5, 2002 3:22 PM About This Manual Operating Manual for XDC Series Slave Power Supply...
  • Page 13: Table Of Contents

    TM-XDSL-01XN.book Page xi Tuesday, November 5, 2002 3:22 PM Table of Contents About This Manual ........... .ix Table of Contents .
  • Page 14: Table Of Contents

    TM-XDSL-01XN.book Page xii Tuesday, November 5, 2002 3:22 PM Table of Contents Operating Manual for XDC Series Slave Power Supply...
  • Page 15: Section 1. Overview

    TM-XDSL-01XN.book Page 13 Tuesday, November 5, 2002 3:22 PM Section 1. Overview The XDC series Slave power supply is designed for use in current sharing systems as a slave module connected in parallel with an XDC 6000 Watt series full digital controlled front panel unit.
  • Page 16: Front Panel

    1. Rack mount brackets 2. Handles 3. ON/OFF Switch 4. Power On status LED (green) 5. Ouput Off status LED (red) Lit when the output is disabled 6. Front panel display (vacuum fluorescent display) Operating Manual for XDC Series Slave Power Supply...
  • Page 17: Section 2. Ac Input Power

    TM-XDSL-01XN.book Page 15 Tuesday, November 5, 2002 3:22 PM AC Input Power Front Panel Section 2. AC Input Power WARNING Disconnect AC power from the unit before removing the connector cover. Live line voltages may be exposed when the cover is removed. WARNING A safety ground wire must be connected to the unit as shown in Figure 2.1 to ensure operator safety.
  • Page 18: Ac Input Connector

    25A. 342–500Vac, 47–63Hz, 4 x 14 AWG (3 wire plus safety ground), stranded ° 3-phase, 4 wire (HV-Input) copper, 60 C minimum, 600V, 0.800 in. maximum cable diameter, rated for 13A. Operating Manual for XDC Series Slave Power Supply...
  • Page 19: Ac Wire Input Connection

    TM-XDSL-01XN.book Page 17 Tuesday, November 5, 2002 3:22 PM AC Input Power AC Wire Input Connection AC Wire Input Connection See Figure 2.2, on page 18. To connect the AC input wires: 1. Ensure that the AC input cord is de-energized, and that the power switch on the front of the power supply is OFF.
  • Page 20 TM-XDSL-01XN.book Page 18 Tuesday, November 5, 2002 3:22 PM AC Input Power AC Wire Input Connection Figure 2.2 Attaching the AC Input Wires Operating Manual for XDC Series Slave Power Supply...
  • Page 21: Section 3. Current Sharing

    TM-XDSL-01XN.book Page 19 Tuesday, November 5, 2002 3:22 PM Current Sharing Overview Section 3. Current Sharing Overview Power supplies equipped with the CANbus interface will allow current sharing between units connected in parallel. Current sharing can use a maximum of 5 supplies, including the master.
  • Page 22: Canbus Setup

    The address is retained in non-volatile memory. Note: Only the first 4 slave units powered on will current share. Note: Only units with the same output ratings will current share. Operating Manual for XDC Series Slave Power Supply...
  • Page 23: Current Share Configuration

    TM-XDSL-01XN.book Page 21 Tuesday, November 5, 2002 3:22 PM Current Sharing Overview Current Share Units are programmed in a mode such that it is already in current sharing mode on Configuration power up. This feature is not user-modifiable. Please contact the manufacturer for assistance if you wish to change this.
  • Page 24: Operation

    (Error +1822). • Specifications Max units on bus Max current share units Max cable length Bus speed 700 kbits/sec. Termination 120 ohm, 1/4 Watt Connections parallel male DB9 to female DB9 cable Operating Manual for XDC Series Slave Power Supply...
  • Page 25: Appendix A. Specifications And Characteristics

    TM-XDSL-01XN.book Page 23 Tuesday, November 5, 2002 3:22 PM Appendix A. Specifications and Characteristics Notes • These specifications are represented over the full operating temperature range. • Nominal line input voltage assumed unless otherwise stated. • All sense lines are configured for default local operation. •...
  • Page 26: Electrical Specifications-Summary

    1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on. 2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up. 3. Change in output per °C change in ambient temperature, with constant line and load. Operating Manual for XDC Series Slave Power Supply...
  • Page 27 TM-XDSL-01XN.book Page 25 Tuesday, November 5, 2002 3:22 PM Specifications and Characteristics Electrical Specifications—Summary Table A.3Specifications for 80V to 600V Models Models 80–75 100–60 150–40 300–20 600–10 Output Ratings: Output Voltage 0–80 V 0–100 V 0–150 V 0–300 V 0–600 V Output Current 0–75 A 0–60 A...
  • Page 28: Ac Line Input Specifications

    C ambient temperature and maximum power ° 4. At 342V input voltage, 50 C ambient temperature and maximum power ° 5. At 400V input voltage, 25 C ambient temperature and maximum power Operating Manual for XDC Series Slave Power Supply...
  • Page 29: Output Performance Specifications

    TM-XDSL-01XN.book Page 27 Tuesday, November 5, 2002 3:22 PM Specifications and Characteristics Output Performance Specifications Output Performance Specifications These specifications define the electrical performance specifications of the power supply output. These specifications apply to both local and remote sense configurations, except where noted. These specifications apply to all programming sources, except where noted.
  • Page 30 0.04% of Vmax Current 0.6% of Imax Power 1% of Pmax 1. Accuracy specifications apply for settings in range of 1% to 100% of rated output 2. At 25°C ±5°C, with full power load Operating Manual for XDC Series Slave Power Supply...
  • Page 31 TM-XDSL-01XN.book Page 29 Tuesday, November 5, 2002 3:22 PM Specifications and Characteristics Output Performance Specifications 8 Hour Drift Temperature Stability Voltage 0.02% of Vmax Current 0.04% of Imax Power 0.1% of Pmax Temperature Coefficients Remote Digital Interface Voltage Programming 0.04% of Vmax /°C /°C Current Programming...
  • Page 32 Time for the output voltage to recover within 0.75% of rated output of its previous level after a step change in load current of up to 50% - 100% and 100% to 50% of rated output Operating Manual for XDC Series Slave Power Supply...
  • Page 33: Environmental Specification

    TM-XDSL-01XN.book Page 31 Tuesday, November 5, 2002 3:22 PM Specifications and Characteristics Environmental Specification Environmental Specification Operating Altitude Up to 6,500 feet (2,000 m) Storage Altitude Up to 50,000 feet (15,000 m) Installation Category II (IEC 1010-1) Pollution Degree 2 (IEC 1010-1) Thermal Specification Operating Temperature Range...
  • Page 34: Mechanical Specification

    TM-XDSL-01XN.book Page 32 Tuesday, November 5, 2002 3:22 PM Specifications and Characteristics Mechanical Specification Mechanical Specification Weight Approx. 75 lb. (34 kg) for 10 V-600 A unit, without packaging Size Figure A.1 Power Supply Dimensions Operating Manual for XDC Series Slave Power Supply...
  • Page 35 TM-XDSL-01XN.book Page 33 Tuesday, November 5, 2002 3:22 PM...
  • Page 36 TM-XDSL-01XN.book Page 34 Tuesday, November 5, 2002 3:22 PM Xantrex Technology Inc. 8999 Nelson Way Burnaby, British Columbia Canada V5A 4B5 604 422 2777 Tel 604 420 2145 Fax 800 670 0707 Toll Free North America customerservice@xantrex.com www.xantrex.com TM-XDSL-01XN PRINTED IN CANADA...

Table of Contents