Auto-Sequence
Auto Sequence lets you recall a stored program next time the unit is powered on.
(Assumes at least one program has been saved in memory. See "To edit the
sequence's trigger source:Using Auto Sequencing" on page 96.)
To select Auto Sequence:
Step # Do This
1
2
3
4
5
6
1. You can also press the Down arrow 2 times.
2. You can also press the Down arrow 3 times.
3. You can scroll through up to 10 stored programs.
Program
The AUTO SEQ PGM menu option is used to set up command programs for
Auto
automated operation. There are 10 programmable sequences with up to 99 steps per
sequence.
Sequence
Each sequence can be repeated a programmable number of times or forever. If the
sequence contains steps that advance by a trigger event, a single trigger source can
be selected to advance those steps.
Each step can be programmed to set the voltage setpoint, current setpoint, power
setoint, and OVP level automatically. Each step can also be programmed to advance
by a delayed time or a trigger event. The duration of each step may range from 10 ms
to 99 hours.
Release 3.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MENU
1
2 times
.
MENU
ENTER
2
3 times
.
MENU
ENTER
3
or
to scroll
to select.
ENTER
Power Supply Operation
You Will See
ERROR MSGS
PON CONFIG
Last Setting
Auto Sequence
Auto Seq 1
,
The default display for the selected
operating mode.
Operation
87

Hide quick links:

Advertisement

Table of Contents
loading