Cord The AC input cord we recommend is specified in Table 2.3, "AC Wire
Specification". Add a non-locking plug suitable for use in the country in which you
are operating. If you require a special cord, call us.
Table 2.3 AC Wire Specification
Wire Size
3 x 12 AWG stranded copper 60 °C minimum, 300 V
AC Input Wire
Connection
1. Strip the outside insulation on the AC cable approximately 4 in. (10 cm). Trim
2. Unscrew the base of the strain relief from the helix-shaped body. Insert the base
3. Slide the helix-shaped body onto the AC cable. Insert the stripped wires through
4. Route the AC wires to the input connector terminals as required. For input
5. Route the wires inside the cover to prevent pinching. Fasten the AC input cover
Release 2.1
WARNING
Ensure that the chassis ground screw does not penetrate more than 3/8 in.
(9 mm) into the rear panel of the unit.
the wires so that the ground wire is 0.5 in. (12 mm) longer than the other wires.
Strip 0.55 in. (14 mm) at the end of each of the wires. See Figure 2.2 detail (top).
through the outside opening in the AC input cover and, from the inside, screw
the locknut securely onto the base.
the strain relief base until the outer cable jacket is flush with the edge of the base.
Tighten the body to the base while holding the cable in place. The cable is now
securely fastened inside the strain relief.
connector terminal locations, see lower inset in Figure 2.2. To connect the
wiring, loosen the terminal screw, insert the stripped wire into the terminal, and
tighten the screw securely.
to the unit using the (6-32 x 1 1/4 in. (2)) screws, flat washers, and lock washers
provided. See Figure 2.2.
Ratings
Installation
AC Input Power
Cable Outside Diameter
0.545-0.708 in.
(13.63-17.7 mm)