AC Input Wire The manufacturer recommends the AC input wire specified in Table 2.2 and
Table 2.3. This must be permanently connected to an approved AC distribution box
with suitably rated over-current protection. If you require a special cord, contact the
manufacturer.
Table 2.2 AC Wire Specification for 6000 Watt units
AC Input Voltage Range
190–242Vac, 47–63Hz,
3-phase, 4 wire (standard)
342–500Vac, 47–63Hz,
3-phase, 4 wire (HV-Input)
Table 2.3 AC Wire Specification for 12000 Watt units
AC Input Voltage Range
190–242Vac, 47–63Hz,
3-phase, 4 wire (standard)
342–500Vac, 47–63Hz,
3-phase, 4 wire (HV-Input)
AC Wire Input
See Figure 2.5, on page 42.
Connection
To connect the 6000 W AC input wires:
for 6000 W
1. Ensure that the AC input cord is de-energized, and that the power switch on the
2. Strip approximately 4 in. (10 cm) from the jacket of the AC wire. Strip 0.55 in.
3. Undo the 2 screws for the AC wiring strain relief/cover on the rear panel.
4. Undo the strain relief screws. Insert the AC input cable through the strain relief
5. Insert the ground wire (green) 0.55 in. (14 mm) into the left-most terminal
Release 3.0
front of the power supply is OFF.
(14 mm) at the end of each wire.
Remove the cover.
until the outer cable jacket is flush with the inside of the strain relief. Tighten the
strain relief cable clamp screws.
location, and tighten securely. (The safety ground wire may alternatively be
connected to the chassis ground stud next to the terminal block, using a suitably
sized ring terminal).
Wire
4 x 10 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 300V, 0.800 in. maximum
cable diameter, rated for 25A.
4 x 14 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 600V, 0.800 in. maximum
cable diameter, rated for 13A.
Wire
4 x 6 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 300V, outside diameter
(OD) of cable is ≤ 1 in., rated for 50 A.
4 x 10 AWG (3 wire plus safety ground), stranded
°
copper, 60
C minimum, 600V, outside diameter
(OD) of cable is ≤ 1 in., rated for 25 A.