Table 4.12 Protection Shutdown Sub-Register - Xantrex XDC 10-600 Operating Manual

6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-600:
Table of Contents

Advertisement

Protection SHUTdown Sub-Register

Table 4.12 Protection SHUTdown Sub-Register

Bit
0
1
2
3
4
5
6
7
8
9
Remote CONtrol Sub-Register
This identifies which remote interface is controlling the unit. Only one bit is active
at a time with the exception of analog control, where voltage or current alone, or both
may be under remote control. Current share mode is considered to be under local
control, even though the user cannot adjust the voltage setting from the front panel.
Release 3.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Bit Weight Bit Name
1
Over VOLTage
2
Under VOLTage
4
Over CURrent
8
Under CURrent
16
Over POWer
32
Under POWer
64
AC Off
128
Over TEMPerature
256
SENSe
512
FOLDback
Remote Operation
SCPI Commands for Digital Interfaces
Description
Over voltage protection has tripped
Under voltage protection has tripped
Over current protection has tripped
Under current protection has tripped
Over power protection has tripped
Under power protection has tripped
AC Off protection has tripped
Over temperature protection has tripped
Sense protection has tripped
Foldback protection has tripped