Table B.5Commands for Calibration
Function
SCPI Command
Restore Factory
[:]CALibration[<channel>]:RESTore
ion
Change Calibration
[:]CALibration[<channel>][:SECure]:CODE <codeword>
Password
Set Calibration State
[:]CALibration[<channel>][:SECure]:STATe
<on-off-state>,<codeword>
Set Analog Current
[:]CALibration[<channel>]:ANALog:<5V|10V>:PROGram:CURRe
Programming Input Level
nt:LEVel {MINimum|MAXimum}
Enter Analog Current
[:]CALibration[<channel>]:ANALog:
Programming Input Data
:{5V|10V}:PROGram:CURRent[:DATA] <current>
Set Analog Voltage
[:]CALibration[<channel>]:ANALog:
Programming Input Level
:{5V|10V}:PROGram:VOLTage:LEVel {MINimum|MAXimum}
Enter Analog Voltage
[:]CALibration[<channel>]:ANALog:
Programming Input Data
:{5V|10V}:PROGram:VOLTage[:DATA] <current>
Set Analog Current
[:]CALibration[<channel>]:ANALog:
Readback Output Level
:{5V|10V}:READback:CURRent:LEVel {MINimum|MAXimum}
Enter Analog Current
[:]CALibration[<channel>]:ANALog:
Readback Output Data
:{5V|10V}:READback:CURRent[:DATA] <current>
Set Analog Voltage
[:]CALibration[<channel>]:ANALog:
Readback Output Level
:{5V|10V}:READback:VOLTage:LEVel {MINimum|MAXimum}
Enter Analog Voltage
[:]CALibration[<channel>]:ANALog:
Readback Output Data
:{5V|10V}:READback:VOLTage[:DATA] <current>
Set Supply Output Current
[:]CALibration[<channel>]:OUTPut:CURRent:LEVel
Level
{MINimum|MAXimum}
Enter Output Current Data
[:]CALibration[<channel>]:OUTPut:CURRent[:DATA]
<current>
Set Supply Output Voltage
[:]CALibration[<channel>]:OUTPut:VOLTage:LEVel
Level
{MINimum|MAXimum}
Enter Output Voltage Data
[:]CALibration[<channel>]:OUTPut:VOLTage[:DATA]
<voltage>
Table B.6Command to Clear all Protection Mechanisms
Function
SCPI Command
Clear Output Protection
[:]OUTPut[<channel>]:PROTection:CLEar
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Query
Restonres the calibration to the constants set
N/A
at the factory
Changes the calibration security code.
No
Change calibration state (mode)
Yes
Set analog programming current calibration
No
level
Set analog programming current calibration
No
data
Set analog programming voltage calibration
No
level
Set analog programming voltage calibration
No
data
Set analog readback current calibration level
No
Set analog readback current calibration data
No
Set analog readback voltage calibration level
No
Set analog readback voltage calibration data
No
Set output current calibration level
No
Set output current calibration data
No
Set voltage output calibration level
No
Set voltage output calibration data
No
Description
Query
Clears the protection mechanism.
N/A