Table 4.9 Operation Status Register - Xantrex XDC 10-600 Operating Manual

6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-600:
Table of Contents

Advertisement

Table 4.9 OPERation Status Register

Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Release 3.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Bit Weight Bit Name
1
CALibrating
2
SETTling
4
RANGing
8
SWEeping
16
MEASuring
32
Waiting for TRIGger
Summary
64
Waiting for ARM Summary Not implemented
128
CORRecting
256
REGulating Summary
512
SHUTdown Summary
1024
Remote CONtrol
Summary
2048
Current SHareSummary
4096
Not Used
8192
INSTrument Summary
16384
PROGram Running
32768
Not Used
Remote Operation
SCPI Commands for Digital Interfaces
Description
Indicates that the supply is in
CALibration Mode.
Not implemented
Not implemented
Not implemented
Not implemented
Indicates if the supply is waiting
for a TRIGger.
Not implemented
Reflects the summary of the
REGulating Sub-Register.
Reflects the summary of the
SHUTdown Sub-Register.
Reflects the summary of the
Remote CONtrol Sub-Register.
Reflects the summary of the
Current Share Sub-Register.
Not used
Not implemented
Indicates that an Automated
Sequence is running.
Not used
145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents