Remote Operation
SCPI Commands for Digital Interfaces
REGulating Sub-Register
This describes the regulating mode. If none of these bits is active, the output
unregulated (UNRegulated) bit is active in the questionable status register.

Table 4.10 REGulating Sub-Register

Bit
0
1
2
SHUTdown Sub-Register
Describes the cause of the power supply shutting down. More than one bit may be
active, and multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have caused the
power supply to shutdown.

Table 4.11 SHUTdown Sub-Register

Bit
0
1
2
146
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Bit Weight Bit Name
Description
1
CV
The power supply is regulating in Constant
Voltage mode.
2
CC
The power supply is regulating in Constant
Current mode.
4
CP
The power supply is regulating in Constant
Power mode.
Bit Weight Bit Name
Description
1
PROTectio
The power supply is shut down by a power
n Summary
supply protection mechanism.
2
INTerlock
The power supply is shut down by INTerlock
signal.
4
COMMand
The power supply is shut down by a command.
Operating Manual for XDC Series Power Supply