Specifications and Characteristics
Output Performance Specifications
User Line Interface
Includes auxiliary status lines, interlock, and external trigger lines.
Maximum Current Sink
Capability, Each Output
Maximum Supply Voltage
Minimum Supply Voltage
Isolation
Switching Frequency
Typical 31 kHz; 62 kHz output ripple
Rise Time
5 to 95% step in output voltage.
Load Condition
No Load
Full Load
Fall Time
For a programmed 95% to 5% step in output voltage.
Load Condition
No Load
Full Load
1. Fall time is ≤ 4s for 300 V and 600 V units.
Time Delay From Power On Until Output Stable
5 s maximum
(Within regulation envelope)
Time Delay From Output Enable Until Output Stable
2 s maximum
(Within regulation envelope)
Output Hold-Up Time – Power Off
Minimum 4 ms (at full load)
240
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
10 mA
15 V
4 V
dc
300 Vdc with respect to chassis
potential or negative output
Time (Max)
100 ms
100 ms
Time (Max)
1
3 s
50 ms
dc