Remote Operation
Remote Analog Operation

Table 4.3 Analog Pin Connections for Power Loop Back

Programming Line Pin #
Remote Interlock Using a Contact Closure
The interlock input may be configured for use with an external voltage free contact.
Connect pins as shown:

Table 4.4 Analog Pin Connections with a Contact Closure

Programming Line Pin #
Closing an external contact across the interlock pins A4/A5 will then enable the unit.
Opening the contact will disable the supply output.
Configure
You may configure the analog programming lines to work in either a 0 to 5V range
Analog
or a 0 to10V range. You may also select whether the voltage, current or both are
controlled with the programming lines. If you select only voltage or only current, the
Control
other will be controlled via the front panel.
Front Panel
First, configure the analog programming lines.
Step # Do This
1
2
3
4
5
6
7
1. You can also press MENU 5 times.
110
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
User Line Pin #
B1
to
B2
to
User Line Pin #
B2
to
B1
to
MENU
1
5 times
ENTER
ENTER
or
Select the input range.
ENTER
A7
A6
A4
A5
You Will See
ERROR MSGS
REMOTE CONFIG
RS-232 Cfg
Analog Cfg
Input 0-5V
0-5V or
0-10V
Setting is saved and menu is exited.
Operating Manual for XDC Series Power Supply

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents