Table E.4 Drift Specifications For 6000 Watt Units (80V To 600V Models) - Xantrex XDC 10-600 Operating Manual

6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-600:
Table of Contents

Advertisement

Table E.4Drift Specifications for 6000 Watt units (80V to 600V Models)
Models
1
Drift (30 minutes):
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
2
Drift (8 hours):
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
3
Temperature Coefficient:
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
3. Change in output per °C change in ambient temperature, with constant line and load.
Release 3.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Specifications and Characteristics
80–75
100–60
150–40
32 mV
40 mV
60 mV
450 mA
360 mA
240 mA
16 mV
20 mV
30 mV
30 mA
24 mA
16 mA
32 mV
40 mV
60 mV
45 mA
36 mA
24 mA
Electrical Specifications—Summary
300–20
600–10
120 mV
240 mV
120 mA
60 mA
60 mV
120 mV
8 mA
4 mA
120 mV
240 mV
12 mA
6 mA
231