Error
code
-220
-221
-222
-225
-231
-240
-241
-282
-284
-285
-290
Release 3.0
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Error Message Description
Parameter error
Indicates that a program data element related error occurred.
Setting conflict
Indicates that a legal program data element was parsed but could not be
executed due to the current power supply state.
Factors that may contribute to this error are:
Remote source - To set most values, the remote source must be correct.
Remote state - To set most values, the unit must be in remote mode.
Calibration mode - when in calibration mode, certain settings will cause as error.
Current share mode - When the unit is in current share mode (other than none)
certain settings will cause an error.
Data out of range
Indicates that a legal command could not be executed because the interpreted
value was outside the legal range as defined by the power supply.
Out of memory
The power supply has insufficient memory to perform the requested operation.
Data questionable
Indicates that measurement accuracy is suspect.
Hardware error (occurs during flash update if there is a failure)
Indicates that a legal program command or query could not be executed
because of a hardware problem in the power supply.
Hardware missing
Indicates that a legal program command or query could not be executed
because of missing power supply hardware; e.g. an option not installed.
Illegal program name
The name used to reference an auto sequence program was invalid or there is
no program selected.
Program currently running
Certain operations dealing with auto sequence programs may be illegal while
the program is running. For example, deleting a running program is not
possible.
Program syntax error
There is an error in the program definition.
Memory use error
Indicates that a user request has directly or indirectly caused an error related to
memory or <data_handle>s. This is not the same as "bad" memory.