Operation
Power Supply Operation
Set V, I, and P
The voltage, current and power setpoints can be limited to less than the supply rating
range to match the tolerance of connected equipment or any other criteria you may
Limits
have.
You can control the voltage, current and power setpoint limits through the SETPT
LIMIT menu option. Once the limits have been changed from the supply's default
rated output, settings outside this range are no longer accepted.
Note Setpoint limits do not apply to the triggered outputs and auto sequence outputs.
To set the voltage limits:
Step # Do This
1
2
3
4
5
6
7
8
100
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MENU
until you see the "SETPT
LIMIT" option
ENTER
ENTER
Use the Voltage knob, arrow keys,
or numeric keypad to enter a value.
The value must be within 0V to
103% of the unit's rated voltage.
ENTER
Use the Voltage knob, arrow keys,
or numeric keypad to enter a value.
The value must be within 0V to
103% of the unit's rated voltage.
ENTER
You Will See
ERROR MSGS
SETPT LIMIT
Voltage Limit
High 0V
High #####V
Low 0V
The Maximum setting is saved and the
Minimum setting appears.
Low #####V
The setting is saved and the display
returns to its default operating mode.