Configure Display; Lock Out Control Knobs - Xantrex XDC 10-600 Operating Manual

6000 watt and 12000 watt series digital programmable dc power supply
Hide thumbs Also See for XDC 10-600:
Table of Contents

Advertisement

Operation
Power Supply Operation
Configure
The DISPLAY CONFIG menu option allows you to select the readback values
displayed when the power supply is operating in its default state.
Display
The factory default is to display voltage and current readback, but you can also
choose voltage and power, current and power, or voltage, current, and power.
This table shows how to access and work with the DISPLAY CONFIG option.
Step # Do This
1
2
3
4
5
1. You can also press MENU repeatedly to bring up the Display Config option.
2. The option, Show V, I, & P is not available in current share mode.
Lock Out
The KNOB LOCKOUT menu option allows you to lock the front panel knobs,
Control
forcing changes to be made via the VOLTAGE and CURRENT keys. Knobs should
be locked out whenever you do not want someone to accidentally adjust the supply
Knobs
settings while the unit is operating in local mode.
To lock out both knobs:
Step # Do This
1
2
3
4
5
6
7
98
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MENU
until you see the "DISPLAY
1
CFG" option
ENTER
Using the arrow keys, select
from Show V and I, Show V and P,
Show I and P, Show V, I, & P
ENTER
MENU
until you see the "KNOB
LOCKOUT" option
ENTER
ENTER
ENTER
You Will See
ERROR MSGS
DISPLAY CFG
Show V, I & P
Show V and I
2
.
The setting is saved.
You Will See
ERROR MSGS
KNOB LOCKOUT
Lock V Knob? N
Lock V Knob? Y
Lock I Knob? N
The Voltage knob is locked out.
Lock I Knob? Y
The setting is saved and the display
returns to its default operating mode.