Load Wiring
For applications using remote sensing, or for improved voltage regulation at the load,
you must limit the voltage drop across each load line. We recommend that you use
Length for
the larger load wiring to ensure a smaller voltage drop (1V maximum), although
Operation
units will compensate for up to 5V drop in each line with the remote sense lines
with Sense
connected.
Lines
Noise and
To minimize noise pickup or radiation, use the shortest possible length of
Impedance
shielded-twisted pair wiring for load lines. Connect the shield to the chassis via a rear
panel mounting screw. Where shielding is not possible or is impractical, twisting the
Effects
wires together offers some noise immunity. When using local sense connections, use
the largest practical wire size to minimize the effects of load line impedance on the
regulation of the supply.