Operation
Power Supply Operation
To set the power limit:
Step # Do This
1
2
3
4
5
6
7
8
9
Slew Rate The slew rate is calculated as a function of change in the output voltage and a given
time interval. The maximum slew rate is 1% rated voltage/150us. The slew rate is
saved upon power off and restored at power on. Output ON/OFF and shutdown are
not affected by the programmable slew rate. These functions have a slew rate of
1%/20ms.
The range of output voltage is 5% - 0.1% of rated voltage.
The range of time interval is 1.5 s - 150 us.
The negative slew rate is limited by the discharge rate of the output capacitors.
During current share, slaves operate with their default slew rate. The master operates
at its programmed slew rate. Hence a programmable slew rate for the system is
achieved. However, this slew rate is limited by the speed of the control loop. The
slaves will return to their programmed slew rate when they exit current share slave
operation.
102
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MENU
until you see the "SETPT
LIMIT" option
ENTER
2 times
ENTER
Use the Voltage and Current knobs,
arrow keys, or numeric keypad to
enter a value. The value must be
within 0W to 103% of the unit's rated
power.
ENTER
Use the Voltage knob, arrow keys, or
numeric keypad to enter a value. The
value must be within 0W to 103% of
the unit's rated power.
ENTER
You Will See
ERROR MSGS
SETPT LIMIT
Voltage Limit
Power Limit
High #####W
High #####W
Low #####W
The Maximum setting is saved and
the Minimum setting appears.
Low #####W
The setting is saved and the display
returns to its default operating mode.
Operating Manual for XDC Series Power Supply