Removing An Eps-150Dc Power Module From An Eps-T2 Tray - Extreme Networks Summit X150 Series Hardware Installation Manual

Summit family
Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

Removing an EPS-150DC Power Module from an EPS-T2 Tray

Warning
Always be sure that the DC circuit is de-energized before disconnecting any cables and
attempting to remove an EPS-150DC power module.
Warning
Removing the DC wiring harness from your facilities DC source voltage must be done by a
qualified, licensed electrician.
To disconnect and remove an EPS-150DC power module:
1
Attach an ESD-preventive strap to your bare wrist and connect the metal end to the an appropriate
ground point on the equipment rack.
2 De-energize the DC circuit.
3 At the back of the system, remove power from the EPS-150DC power module by unplugging the DC
connector from the DC power supply socket on the rear of the EPS-150DC unit.
a Loosen the retainer nut on the DC power connector and unplug the connector from the back of
the power unit.
4 At each end of the redundant power cable, unscrew the captive retaining screws on the power
connector and disconnect the cable from the switch and the EPS-150DC unit.
5 Loosen the thumbscrews on the front of the EPS-150DC unit until they are completely free of the
EPS-T tray, and slide the EPS-150 unit out of the tray.
Summit Family Hardware Installation Guide
Replacing DC Power Supplies in Summit Family Switches
351

Hide quick links: