Table 201: Summit X450e-48p Power (continued)
Inrush current
Power supply cord type
Power supply input socket
Power cord input plug
Power cord wall plug
Power supply cord gauge
Efficiency
Heat dissipation with PoE full load
Power consumption with PoE full load
Heat dissipation without PoE
Power consumption without PoE
Table 202: Summit X450e-24t Power
Operational voltage range
Nominal input ratings
Nominal input current
Line frequency range
Inrush current
Power supply cord type
Power supply input socket
Power cord input plug
Power cord wall plug
Power supply cord gauge
Heat dissipation, Watts, BTU
Power consumption, Watts, BTU
Table 203: Summit X450e-48t Power
Operational voltage range
Nominal input ratings
Summit Family Hardware Installation Guide
30 A @ 115 V, 60 A @ 230 V
AC
IEC 320 C14
IEC 320 C13
Refer to
Power Cord Requirements for AC-Powered Switches and AC
Power
Supplies.
2
18 AWG (0.75 mm
) up to 6 feet or 2 meters
or
2
16 AWG (1.0 mm
) over 6 feet
80% with 60% to 100% load
180 W (614 BTU/hr)
507 W (1,730 BTU/hr)
73 W (250 BTU/hr)
73 W (250 BTU/hr)
90 to 264 V
100 to 240 V
, 50/60 Hz, 1.0 A
0.52 A @ 100 V
(low-line)
0.31 A @ 240 V
(high-line)
47 to 63 Hz
30 A @ 115 V, 60 A @ 230 V
AC
IEC 320 C14
IEC 320 C13
Refer to
Power Cord Requirements for AC-Powered Switches and AC
Power
Supplies.
2
18 AWG (0.75 mm
) up to 6 feet or 2 meters
or
2
16 AWG (1.0 mm
) over 6 feet
52 W (178 BTU/hr)
52 W (178 BTU/hr)
90 to 264 V
100 to 240 V
, 50/60 Hz, 6 A