Installing an EPS-150DC Power Supply
Note
Install the EPS-T2 before you begin installing the EPS-150DC.
Warning
Always be sure that the DC circuit is de-energized before connecting or disconnecting the DC
wiring harness at the DC power socket on the rear of the EPS-150DC unit, and before
connecting or disconnecting the redundant power cord between the switch and the
EPS-150DC unit.
Installing an EPS-150DC unit consists of the following tasks:
Connecting the DC wiring harness to the DC source voltage (see the next section).
This task must be performed by a licensed, qualified electrician.
Installing an EPS-150DC unit in an EPS-T2 (see
Connecting the DC wiring harness to the DC power socket on the EPS-150DC (see
Wiring Harness to the DC Power Socket on the
Connecting the EPS-150DC to a switch (see
Perform these four tasks in the order they are described.
Connecting the DC Wiring Harness to the DC Source Voltage
A three-wire, 6-foot long DC wiring harness
included with the EPS-150DC unit. The DC wiring harness must be properly connected to the DC source
voltage at your facility by a qualified electrician before the connector on the wiring harness can be
attached to the DC power supply socket on the rear of the unit. See
information about connector pinouts and for DC power specifications to be used in connecting the
wiring harness to the DC source voltage.
Warning
Wiring the EPS-150DC DC wiring harness to your facilities DC source voltage must be
performed by a qualified, licensed electrician. After the wiring harness is connected to a
permanent DC voltage source by a qualified, licensed electrician, you can remove, replace
and maintain the ESP-150DC without further electrician assistance. However, always be sure
that the DC circuit is de-energized before connecting or disconnecting the DC power
connection at the rear of the EPS-150DC unit.
Caution
The DC wiring harness must be properly connected to a DC main circuit breaker or fuse rated
no greater than 20 A.
Provide proper connection and strain relief on the DC wiring harness in accordance with all
local and national electrical codes.
Summit Family Hardware Installation Guide
Installing Summit External Power Supplies
Install an EPS-150DC Unit into an
EPS-150DC)
Connect the EPS-150DC to a
(Figure 283: Three-wire Cable Harness
Technical Specifications
EPS-T2)
Connect the DC
Switch)
on page 306) is
for
305

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents