Table 70: POE Power Behavior
Internal Power
EPS-600LS (1x)
Supply Status
Internal Power
370 W of
Supply:
redundant power
Power On
Internal Power
370 W of
Supply:
external power only
Power Failure
Single 600-LS Module Configuration: Redundant PoE Power
A single EPS-600LS power module provides redundant PoE power capability with the same 370-watt
capacity as the internal power supply.
The internal Summit X450e-48p or X250e-48p power supply is capable of 370 W of PoE power: 15.4 W
supplied to each port for a 24-port configuration and 7.7 W supplied to each port for a 48-port
configuration.
If the internal power supply fails, the external power module will provide power to PoE devices at
the same power levels as the internal power supply without any power interruptions.
If the EPS-600LS power module fails or is removed, the internal power supply continues to provide
PoE power without any power interruptions.
Dual 600-LS Module Configuration: Full Power
Two EPS-600LS power modules provide full power at 740 W; this power level allows 15.4 W of PoE
power to all 48 ports.
In this full-power configuration, the internal power supply is disabled, and therefore redundant power is
not available.
Triple 600-LS Module Configuration: Full Redundant Power
Three EPS-600LS power modules provide the full 740 W of power for 15.4 W of PoE power to all 48
ports.
In addition, this configuration provides 2:1 redundancy. If one of the EPS-600LS power modules fails,
the third power module continues to provide uninterrupted full PoE power. The internal power supply
is disabled in this configuration.
Internal-to-External Power Supply Transfer
This section describes the conditions that would cause the Summit X450e-48p or X250e-48p switch to
draw power from the external power unit.
Summit Family Hardware Installation Guide
EPS-600LS (2x)
EPS-600LS (3x)
740 W of
740 W of
external power only
external power only
Internal power supply
with 2 + 1 redundancy
disabled
Internal power supply
disabled
740 W of
740 W of
external power only
external power only
with 2 + 1 redundancy
Summit Power Supplies
External Power Supply/
Chassis Failed/
Disconnected
370 W of
internal power only
No PoE power