Extreme Networks Summit X150 Series Hardware Installation Manual page 66

Summit family
Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

Table 21: Front Panel
Label or Type
MGMT
FAN
PSU-I
(Internal power
supply)
PSU-E
(External power
supply)
Port number
1 – 8 or
1 – 24 or
1 – 48
Summit Family Hardware Installation Guide
Color/State
Meaning
Blinking green
Power-on self-test (POST) in progress.
Steady green
POST passed. Normal operation.
Blinking amber
System is disabled. POST failed or system overheated.
Off
No external power attached.
Steady green
Normal operation, fan is good.
Blinking amber
Fan failure. Switch will continue to operate unless it overheats.
Off
No power
Steady green
Normal operation.
Steady amber
Power is attached, but no power is on.
Blinking amber
Power failure.
Off
No power is attached.
Steady green
Normal operation.
Steady amber
Power is attached, but no power is on.
Blinking amber
Power failure.
Off
No external power attached.
Steady green
Link is OK.
Blinking green
Port is transmitting packets.
Off
Link is not present, or port is disabled.
Summit Family Switches
Note
For the following Summit models, fan light is "ON"
only when the fan is running:
Summit X440-24t model No. 800471-00 Revision
6 or lower
Summit X440-24t-10G model No. 800475-00
Revision 5 or lower
Summit X440-L2-24t model No. 800526-00
Revision 1
Note
For the following Summit models, fan light "OFF"
indicates either no power to the fan or temperature is
below threshold where fans are needed:
Summit X440-24t model No. 800471-00 Revision
6 or lower
Summit X440-24t-10G model No. 800475-00
Revision 5 or lower
Summit X440-L2-24t model No. 800526-00
Revision 1
66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents