The Summit X480 and X670 switches have two bays for hot-swappable power supplies. In a switch
with a redundant power configuration, you can replace one Summit AC power supply without
powering down the switch.
Note
You cannot combine 450 W power supplies and 550 W power supplies in the same Summit
X670seriesswitch.
To replace a Summit 450 W or 550 W AC power supply:
1
Disconnect the AC power cord from the wall outlet and from the power supply.
2 Note the orientation of the installed power supply.
3 For a Summit X670 series switch, note the direction of ventilation airflow, and verify that the power
supply airflow direction is the same as that of the switch.
In a switch with front-to-back airflow, the fan modules are labeled Air Out.
In a switch with back-to-front, the fan modules are labeled Air In.
4 Push the latching tab toward the power supply handle and pull outward on the handle to disengage
the power supply internal connectors (see the figure below).
Figure 309: Removing a Summit 450 W or 550 W AC Power Supply
5 Carefully slide the power supply the rest of the way out of the switch.
Caution
Power supplies may become very hot during operation. Wear thermal protective gloves
when you remove a power supply from an operating switch.
Note
If you are not installing a replacement power supply, install a cover over the unoccupied
power supply bay. Unoccupied bays must always be covered to maintain proper system
ventilation and EMI levels.
6 Verify that the replacement power supply is oriented the same way as the unit you removed.
a For a Summit X670 series switch, verify that the airflow direction of the power supply matches
the airflow direction of the switch.