Web Browser/HTTP Problem

In some cases you may not be able to browse the printer Web page simply
because the ethernet HTTP may be turned off.
If you cannot ping the ethernet IP address, make sure the IP address, subnet
mask, and default gateway are set correctly by checking the ETHERNET
PARAMS menu from the control panel. See the InfoPrint 6500 Line Matrix
Printers: User's Manual for configuration menu information.
If you can ping the ethernet IP address but cannot access the Web pages,
perform the following procedure to verify the ethernet HTTP is turned on:
1. Telnet into the ethernet and log in as root with no password.
2. At the system prompt, enter the following commands:
config http on
save
reset
3. After approximately 5 minutes, point your browser to the ethernet IP
address. The printer Web pages should now be accessible.