Show Sntp - D-Link xStack Reference Manual

Dgs-3120 series layer 3 managed gigabit switch
Hide thumbs Also See for xStack:
Table of Contents

Advertisement

®
xStack
DGS-3120 Series Layer 3 Managed Gigabit Switch CLI Reference Guide
DGS-3120-24TC:admin# config sntp primary 10.1.1.1 secondary 10.1.1.2 poll-
interval 30
Command: config sntp primary 10.1.1.1 secondary 10.1.1.2 poll-interval 30
Success.
DGS-3120-24TC:admin#
107-2 config sntp ipv6server
Description
This command is used to configure the SNTP IPv6 server information.
Note: If both SNTP IPv4 and IPv6 servers are configured, the SNTP IPv4 server has higher
priority, the Switch's time syncs with the IPv4 server's time first.
Format
cconfig sntp ipv6server {primary <ipv6addr> | secondary <ipv6addr>}(1)
Parameters
primary - (Optional) SNTP primary server IPv6 address.
<ipaddr> - Enter the IP address used for this configuration here.
secondary - (Optional) SNTP secondary server IPv6 address.
<ipaddr> - Enter the IP address used for this configuration here.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure SNTP:
DGS-3120-24TC:admin#config sntp ipv6server primary 1000::1 secondary 1000::2
Command: config sntp ipv6server primary 1000::1 secondary 1000::2
Success.
DGS-3120-24TC:admin#

107-3 show sntp

Description
This command is used to display SNTP current time source and configuration.
Format
show sntp
995