Tdm-Clk (Tdm Bus Clock) - Avaya S8700 Maintenance Manual

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

TDM-CLK (TDM Bus Clock)

TDM-CLK (TDM Bus Clock)
MO's Name (in
Alarm Log)
TDM-CLK
TDM-CLK
TDM-CLK
1.
UU is the universal cabinet number (1–64). C is the carrier designation (A, B, C, or D).
NOTE:
Replacing the Tone-Clock circuit pack requires a special procedure
described in the documentation for TONE-BD. That section also describes
the LED displays for this board.
The Time Division Multiplex (TDM) Bus Clock resides on the Tone-Clock circuit
pack, providing clocking signals both for the TDM bus and the LAN Bus. The
Tone-Clock circuit pack is a critical component in the system and is necessary to
ensure the operation of every port circuit pack in the system. The TDM buses of
the PPN and any EPNs are synchronized together. The system timing reference
can be derived internally from the Tone-Clock circuit pack in any PN, or from an
external (off-board) timing reference. Currently, the TDM bus Clock supports
synchronizing the TDM bus with interface rates from Digital Signal 1 (DS1)
facilities as primary or primary and secondary references.
Moreover, the Tone-Clock circuit pack aids in monitoring and selecting
synchronization references. The Tone-Clock circuit pack, after detecting that the
external source of timing is not valid, will automatically begin its escalation
procedure, according to the facilities administered. In the following table,
successive losses of signal cause escalation from left to right.
NOTE:
Switching back to a DS1 source is handled by synchronization maintenance,
once any problems with it have been corrected and tested.
Tone-Clock
Synchronization
Role
Facilities
MASTER
DS1 Primary and
Secondary
DS1 Primary Only
No External Source
See
''SYNC (Port-Network Synchronization)'' on page 8-1034
about the escalation plan. There is a strong interdependency among the DS1
Interface circuit pack's Maintenance, Synchronization Maintenance, and TDM Bus
Clock Maintenance MOs.
555-233-142
Alarm Level
Initial Command to Run
MAJOR
test tone-clock UUC short
MINOR
test tone-clock UUC short
WARNING
release tone-clock UUC
Initial External
Synchronization
Source
DS1 Primary
DS1 Primary
None
1
Full Name of MO
TDM bus Clock
TDM bus Clock
TDM bus Clock
Backup External
Synchronization
Internal
Source
Source
DS1 Secondary
Local
oscillator
None
None
for more details
Issue 1 May 2002
8-1123

Advertisement

Table of Contents
loading