Maintenance Object Repair Procedure
e. Error Type 513 — Circuit pack detected and reported hardware failure.
1. Reset the circuit pack (reset board UUCSS).
4352
4353
4355
4356
4357
f. Error Type 769 — Logic error. By itself this error can be ignored, but it can
result in other error types being reported.
g. Error Type 1281,1290–1295 — Critical hardware or firmware error.
If the switch detects:
1 error,
3 errors in 15 minutes,
Error Type descriptions are as follows:
1290
1291
1292
1293
1294
1295
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
h. Error Type 1537, 1796 — A hyperactive VAL circuit pack that has
exceeded the error threshold has been removed from service.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
i. Error Type 1794 — Packet bus transmit buffers have overflowed.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
8-1322
Issue 1 May 2002
Aux Data:
External RAM error
Internal RAM error
ROM Checksum error
Angel Message Corruption error
Instruction set error
Then the switch:
Resets circuit pack.
Raises MINOR alarm.
Global HDLC error
Main RAM/ROM error
CPU error
Insane on-board processor
On-board translation RAM error
(Aux 3) RSCL link down
(Aux 0) RSCL keep alive failure
555-233-142