Maintenance Object Repair Procedure
k. Error Type 1537—LAN Bus Timeout; the circuit pack transmitted too many
bytes on the LAN bus for a single frame. This condition may be caused by:
If the error occurs 3 times within 10 minutes, the system raises the board
alarm and isolates it from the packet bus.
1. Clear the alarm and restore the board to the packet bus using the
2. If the problem persists, and there are no PKT-BUS alarms or port
l. Error Type 1538—Hyperactive circuit pack is out-of-service and may
exhibit one or more of the following symptoms:
The circuit pack is isolated from the system, and every trunk or port on this
circuit pack is placed into the out-of-service state. The system attempts to
restore the circuit pack within 20 – 30 minutes. When no faults are
detected for 20 – 30 minutes, the MAPD Interface circuit pack is restored to
normal operation, and every trunk or port on the MAPD Interface circuit
pack returns to the in-service state.
1. If the board is not restored to normal operation or the error recurs
m. Error Type 3073 – 3160—Board is reporting slip errors. Aux Data shows
the last reported slip count.
8-732
Issue 1 May 2002
an on-board fault
faulty data received on one of the circuit pack's external ports. If
any of the ports on this circuit pack are alarmed, refer to the repair
procedures for those MOs.
following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS long clear
d. release board UUCSS
alarms, then replace the circuit pack. See
the TN802''
before removing the circuit pack.
The common circuit pack tests (for example, Test #50 and/or Test
#52) abort with Error Code 2000.
Port tests on this circuit pack return NO-BOARD.
A busyout/release of the circuit pack has no effect on test results.
A list configuration command shows that the circuit pack and ports
are properly installed.
after the board is restored to normal operation, escalate the
problem.
''Shutting Down NT on
555-233-142