Avaya S8700 Maintenance Manual page 93

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

MMI-BD
System Technician-Demanded Tests:
Descriptions and Error Code
Always investigate tests in the order presented in
inspecting errors in the system. For example, by clearing error codes associated
with the TSI Crosstalk test (#6), you may also clear errors generated from other
tests in the testing sequence.
Table 8-338. System Technician-Demanded Tests: MMI-BD
Order of Investigation
TSI Crosstalk test (#6)
TSI Loop-around test (#1108)
MMI SYNC Status test (#1123)
MMI SYNC Status test (#1122)
Control Channel Loop-around test (#52)
2
SAKI Sanity test (#53)
1.
D = Destructive, ND = Nondestructive
2.
Refer to the repair procedure described in
description of this test.
TSI Crosstalk Test (#6)
This test is nondestructive.
The Time Slot Interchanger (TSI) chip controls connectivity to the TDM bus. The
TSI Cross Talk test verifies that this TSI talks on the selected TDM bus time slot
and never crosses over to time slots reserved for other connections. If the TSI is
not working correctly, one-way and noisy connections may occur. If the test
passes, then the TSI can communicate over the TDM bus. This test is part of the
circuit pack's demand and scheduled long test sequence, and takes
approximately 20 to 30 seconds to complete.
555-233-142
Short Test
Long Test
Sequence
Sequence
X
X
X
X
2
X
X
''XXX-BD (Common Port Circuit Pack)'' on page 8-1374
Table 8-338
below when
Reset Board
Sequence
X
Continued on next page
Issue 1 May 2002
1
D/ND
ND
ND
ND
ND
ND
D
for a
8-789

Advertisement

Table of Contents
loading

Table of Contents