Maintenance Object Repair Procedure

Digit Detection Test (#297)

This test is executed on the Non-Control Channel bus. The Tone-Clock circuit
pack is told to put a tone on the Non-Control Channel bus and the Tone Detector
circuit pack is told to listen to it. The test passes if the tone is successfully
transmitted on the Non-Control Channel bus.
Table 8-478. Test #297 Digit Detection Test
Error
Test
Code
Result
Description / Recommendation
None,
ABORT
Could not allocate the necessary system resources to run this test.
1001,
2100
1005
ABORT
Since this test is valid only on the non-control channel bus, it aborts execution
when run on the control channel bus. This is a valid response. Use the status
port-network command to verify which bus is the control channel bus.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
None
FAIL
This failure indicates that communication on the Non-Control Channel is not
reliable.
1. Execute the command again.
2. If the problem persists, test the active Tone-Clock circuit pack and Tone
3. Execute the command again.
4. If the problems persists, see
PASS
The non-control channel bus is operational.
8-1122
Issue 1 May 2002
Detector circuit pack in the port network where the faulted TDM bus
resides, to make sure they are healthy. See
Circuit
Pack)'',
''TONE-PT (Tone
(General-Purpose Tone Detector
Multifrequency Receiver Port)''
''TONE-BD (Tone-Clock
Generator)'',
''GPTD-PT
''DTMR-PT (Dual-Tone
Port)'', and
.
''TDM-Bus Fault Detection and
Continued on next page
Isolation''.