Avaya S8700 Maintenance Manual page 201

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

PDMODULE (Processor Data Module) TDMODULE
(Trunk Data Module)
For this test to run, the Remote Loop-Around Test field on the Data Module
administration form must be set to y, indicating that the data module endpoint
supports the test.
Switch
TN771
Maintenance/
Test circuit
pack
Figure 8-34. Internal Loop-Around Test
A signaling message is sent through the digital port circuit pack to the data
module, requesting it to enter loop-around mode. A test pattern is then sent from
the TN771D Maintenance/Test circuit pack, over the path illustrated above, and
back to the TN771D where it is checked for consistency.
The test aborts if any of the following local PBX resources are not available: a
digital port on the TN771D (there are two such digital ports, but only one may be
used at a time), two TDM time slots and an idle digital port connected to the data
module.
555-233-142
TDM
bus
Digital
line
circuit
pack
Data module
(MPDM, DA, MTDM)
pdmodul2 LJK 072501
Issue 1 May 2002
Data
equipment
8-897

Advertisement