Maintenance Object Repair Procedure

TDM Bus Clock Parameter Update Test (#151)

This test updates the following internal parameters on the IPSI circuit pack:
Disable in-line duplication status messages.
Set the PPM threshold at 85 PPM for TN2312.
Enable PPM threshold switching
Set the number of slips to trigger loss of signal - currently 30 per
5-millisecond period
Enable the on-board synchronization switching algorithm (see above)
Enable holdover operation
This is not a test and will always pass without identifying or reporting any IPSI
circuit pack errors
Table 8-484. Test #151 TDM Bus Clock Parameter Update Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The IPSI circuit pack parameters have been successfully updated.
8-1132
Issue 1 May 2002
Continued on next page