Avaya S8700 Maintenance Manual page 586

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-536. Test #1210 CSU Equipment Loop-Back Test — Continued
Error
Test
Code
Result
Description / Recommendation
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
2. Retry the command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the IPSI circuit pack via
the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950
ABORT
Another loopback/span test is already executing on the DS1 board or the board
is in a network-requested loop-back mode (line loopback or payload loopback).
The hardware error log will indicate whether a Customer Loop-Back Jack test,
Far CSU Loopback test, or the One-Way Span test is executing or if the board
is in line-loopback or payload-loop-back mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a loopback/span test
is already active, that test must be terminated using the test ds1-loop UUCSS
end-loopback/span-test command in order to execute this test.
1951
ABORT
The CSU Equipment Loopback test could not be executed because the 120A1
CSU module was not physically installed. Physically connect the 120A1 CSU
module to the UDS1-BD board behind the port carrier.
8-1282
Issue 1 May 2002
the UDS1 Interface circuit pack into the out-of-service state.
Continued on next page
555-233-142