Avaya S8700 Maintenance Manual page 115

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

MODEM-PT (Modem Pool Port)
Error Log Entries and Test to Clear Values
Table 8-346. Modem Pool Port Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
18
0
busyout UUCSS
2
130
None
257
Conversion Resource Loop
(#98)
513
Modem Conference (#97)
769
Modem NPE Crosstalk (#96)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
This error type indicates that the circuit pack has been removed or has been insane for more than 21 minutes.
To clear the error, reinsert or replace the circuit pack.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Modem Pool Conference test (#97), you may also clear errors generated from
other tests in the testing sequence.
Order of Investigation
Modem Pool NPE Crosstalk test (#96)
Modem Pool Conference test (#97)
Modem Pool Conversion Resource
Loop-around test (#98)
Modem Pool Audits test (#99)
1.
D = Destructive, ND = Nondestructive
NOTE:
The tests in this section do not apply to Combined Modem Pool conversion
resources. The standard Digital Line and/or Analog Line port tests are run
on the ports associated with the Combined Modem Pool. Consult the test
descriptions for those MOs when repairing Combined Modem Pool
arrangements.
555-233-142
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test port UUCSSpp sh r 1
WARNING
OFF
release port UUCSS
WARNING
ON
test port UUCSSpp sh
MINOR
ON
test port UUCSS s r 3
MINOR
ON
test port UUCSS l r 3
MINOR
ON
test port UUCSS l r 3
Short Test
Sequence
X
X
Issue 1 May 2002
Long Test
1
Sequence
D/ND
X
D
X
D
X
ND
X
ND
8-811

Advertisement

Table of Contents
loading