Avaya S8700 Maintenance Manual page 85

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

MET-LINE (MET Line)
Table 8-334. Test #61 MET Line Station Audits Test — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
Hybrid Line Station audits passed.
1. Although this test will never actually return a FAIL result except for the
2. If these errors appear in the Error Log, or if user complaints persist,
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
555-233-142
Internal system error described above, it is possible that it will enter Error
Type 257 or 513 into the Error Log. To determine whether there are any
problems that don't show up in the test result, look for these error types in
the Error Log.
investigate by using other circuit pack tests, and by examining the station,
wiring, and connections.
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, check to
ensure that there is a valid board inserted.
Continued on next page
Issue 1 May 2002
8-781