Avaya S8700 Maintenance Manual page 122

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Table 8-349. Test #98 Modem Pool Conversion Resource
Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1182
ABORT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340
ABORT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
2. If the ports are present and no errors are logged against them, retry the
3. If the test continues to abort, replace the Maintenance/Test circuit pack.
2004
ABORT
Off-Hook was not received from the Pooled Modem.
1. Busyout the digital port being tested on the Pooled Modem circuit pack.
2. If the test still aborts, replace the circuit pack.
2005
ABORT
The Maintenance/Test and the Pooled Modem boards' digital ports failed to
handshake.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test still aborts, replace the Pooled Modem circuit pack.
2312
ABORT
The Loop-around test did not complete, failed to receive loop-back data.
1. Retry the test, if still aborts, replace the Pooled Modem board.
2313
ABORT
The Maintenance/Test board's digital port allocated for this test did not respond
to down-linked message.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, replace the MTB.
2314
ABORT
The Modem Pool digital port did not respond to downlinked message. This
error is internal to the Modem Pool circuit pack and does not involve external
equipment or interfaces.
1. Busyout the TN758 Pooled Modem conversion resources on the circuit
2. If the test continues to abort, replace the Pooled Modem circuit pack and
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
8-818
Issue 1 May 2002
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. Because at least one Maintenance/Test circuit pack must always
be present in the PPN of any G3r system, there should be at least two such
ports present. If the ports are present, proceed to step 2. Otherwise,
determine why no ports appear in the list config display.
command at 1-minute intervals up to 5 times.
Retry the command at 1-minute intervals up to 5 times.
pack.
retest.
Continued on next page